Electrical Grid Monitoring

Protect cables, towers and substations from strikes and theft.

Buried HV cables and transmission corridors are exposed to third-party excavation, tower tampering and copper theft. SABREFONIC listens along the route and alerts the grid operator while machinery is still approaching.

300 mmachinery detection
±10 malarm location
±0.5 °Ctemperature change
100+ kmper interrogator
Scenario

How SABREFONIC responds.

Sensing fibreDetected event
CONTROL ROOM · MONITORING
Chainage—
Class—
Confidence—
    Replay · alarms are pushed to PSIM / VMS via open API
    The challenge

    Why conventional sensors fall short.

    CHALLENGE 01

    Cable strikes

    A single excavator strike on an HV cable causes outages, repair costs and safety risk.

    CHALLENGE 02

    Tower and copper theft

    Earthing straps, tower members and copper cables are stolen from remote sites.

    CHALLENGE 03

    Substation intrusion

    Unmanned substations need perimeter detection without adding field electronics.

    What SABREFONIC detects

    Typical distances from the cable. Final values are confirmed in the site survey and pilot.

    EventDescriptionRange
    ExcavationMachinery and manual digging near buried cables15–300 m
    Tower tamperingClimbing, cutting or impacts on lattice towersby profile
    Substation intrusionFence climbing and cuttingon fence
    Cable theftTampering and cutting on cable routeslocated ±10 m
    Temperature changeChange along the cable route±0.5 °C

    Recommended installation

    Chosen after a free route survey.

    • Buried cable routes: sensing fibre in the cable trench or a spare core in the pilot cable.
    • Overhead lines: spare cores in the OPGW earth wire, subject to survey.
    • Substations: fence-mounted fibre on the same interrogator.

    Integration

    Alarms reach the people who act on them.

    • SCADA and EMS alarms via Modbus
    • Work-permit check against the alarm location
    • PTZ cameras at substations
    • Field crew dispatch with chainage
    FAQ

    Common questions.

    Can we use OPGW fibre on our overhead lines?

    Often yes, using a spare single-mode core. The survey confirms which events can be detected given how the OPGW is mounted.

    Can it ignore authorised works?

    Yes. Known work zones can be masked for the duration of a permit, while everything outside them stays protected.

    Does it need power along the line?

    No. The fibre is passive. Only the interrogator at the substation or control room needs power.

    Protect your electrical grid with SABREFONIC.

    Tell us about the asset you need to protect. Our engineers will review your route and existing fibre and propose a DAS design, free of charge.